Компанияның кіріспе
алдыңғы бет > Заттаңба > Мұнай батырмасымен трансформаторларды қорғау конфигурациясы

Мұнай батырмасымен трансформаторларды қорғау конфигурациясы

Oil-Immersed Transformer Protection Configurations Oil-immersed transformers are critical components in power systems, requiring robust protection schemes to ensure safe and reliable operation. Protection configurations for these transformers are designed to detect and mitigate faults, prevent equipment damage, and minimize system disruptions. Below are the key protection elements commonly applied to oil-immersed transformers. 1. Differential Protection Differential protection is the primary scheme for detecting internal faults, such as winding short-circuits or turn-to-turn faults. It compares the current entering and leaving the transformer windings. Any imbalance indicates an internal fault, triggering an instantaneous trip. This scheme is highly sensitive and selective, ensuring fast isolation of faults while avoiding unnecessary trips for external disturbances. 2. Overcurrent Protection Overcurrent relays (e.g., IDMT or definite-time) protect against external faults or overloads. These relays monitor phase currents and operate if currents exceed predefined thresholds. Time delays are often applied to coordinate with downstream protection devices, ensuring selective tripping. 3. Buchholz Relay A mechanical Buchholz relay is installed in the oil pipe between the transformer tank and conservator. It detects gas accumulation (from minor faults like partial discharges) or sudden oil flow (from severe faults like winding short-circuits). For minor faults, it issues an alarm, while severe faults trigger an immediate trip. 4. Overload and Thermal Protection Thermal relays or winding temperature indicators (WTIs) monitor oil and winding temperatures. Overload conditions cause excessive heating, which can degrade insulation. WTIs provide alarms or trips based on temperature thresholds, preventing long-term damage. 5. Earth Fault Protection Restricted earth fault (REF) protection detects ground faults within the transformer windings. It uses a high-impedance relay connected to neutral current transformers (CTs) and provides sensitive fault detection while remaining stable during external faults. 6. Overvoltage Protection Surge arresters and overvoltage relays protect against lightning strikes or switching surges. These devices divert high-voltage transients away from the transformer, while relays trip if sustained overvoltages threaten insulation integrity. 7. Pressure Relief Device A pressure relief valve activates if internal faults generate excessive gas pressure, preventing tank rupture by releasing pressure and initiating a trip signal. 8. Oil Level and Quality Monitoring Low oil level alarms or trips prevent operation with insufficient cooling. Oil quality sensors detect moisture, acidity, or dissolved gases (via DGA—Dissolved Gas Analysis), providing early warnings for insulation degradation. Conclusion A comprehensive protection scheme for oil-immersed transformers combines electrical, mechanical, and thermal safeguards. Differential and Buchholz relays address internal faults, while overcurrent, earth fault, and thermal protection handle external faults and abnormal operating conditions. Backup protections like pressure relief and surge arresters enhance resilience. Proper coordination ensures rapid fault clearance, minimizing damage and maintaining system reliability. (Word count: 500)

өнім

Әзірге іздеу нәтижелері жоқ!

жаңалықтар

Классификация:
Әзірге іздеу нәтижелері жоқ!

іс

Классификация:
Әзірге іздеу нәтижелері жоқ!

бейне

Классификация:
Әзірге іздеу нәтижелері жоқ!

жүктеп алу

Классификация:
Әзірге іздеу нәтижелері жоқ!

жұмысқа қабылдау

Классификация:
Әзірге іздеу нәтижелері жоқ!

Ұсынылатын өнімдер

Әзірге іздеу нәтижелері жоқ!
55/17 Қазақстан Республикасы
Бізге қоңырау шалыңыз: +861808409399

Бұл веб-сайт біздің веб-сайтта ең жақсы тәжірибе алуыңызды қамтамасыз ету үшін cookie файлдарын пайдаланады.

Қабылдау бас тарту